Chapter 16: Unit Management (CLI)
Upgrading the Software (CLI)
phn-3965_006v002
Page 16-15
Installing and Upgrading Software (CLI)
To install or upgrade the software, enter the following command in root view after downloading the software
bundle:
root> platform software install version
To display the status of an IDU software installation or upgrade, enter the following command:
root> platform software install status show
Installing and Upgrading Software in the RFU (CLI)
RFU software is installed and upgraded per carrier. After downloading a new software bundle, you must enter the
following two commands in root view to install the new RFU software version in a carrier:
root> platform software update rfu version slot <slot> radio-port <radio-
port>
root> platform software install rfu version slot <slot> radio-port
<radio-port>
To view the status of an RFU installation or upgrade procedure, enter the following command in root view:
root> platform software rfu status show
To display all RFU software versions currently running in the unit, enter the following command:
root> platform software show rfu versions
Table 151
RFU Software Upgrade CLI Parameters
Parameter
Input Type
Permitted Values
Description
slot
Number
1
port
Number
1-2
After installing the new version, it is recommended that you verify the installation by entering the
platform
software show rfu versions
command to verify that the new version has been properly installed.
The following sequence of commands installs RFU-C software version 2.13 in radio interface 1.
First, enter the following command to determine which software versions are available, and which software
versions are installed and running:
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...