Chapter 7: Quality of Service (QoS)
Configuring WRED
phn-3965_006v002
Page 7-27
Assigning WRED Profiles to Queues
To assign a WRED profile to a queue:
1.
Select
Ethernet > Interfaces > Logical Interfaces
. The Logical Interfaces page opens (
2.
Select an interface in the Ethernet Logical Port Configuration table and click
WRED
. The WRED page opens.
Figure 236
Logical Interfaces
–
WRED Page
3.
In the
Show Service bundle ID
field, select 1.
Note
Service Bundles are bundles of queues, grouped together in order to configure common egress
characteristics for specific services. In the current release, only Service Bundle 1 is supported.
4.
Select a CoS Queue ID and click
Edit
. The Logical Interfaces
–
WRED
–
Edit page opens.
Figure 237
Logical Interfaces
–
WRED - Edit Page
5.
In the
Profile ID
field, select the WRED profile you want to assign to the selected queue.
6.
Click
Apply
, then
Close
.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...