Chapter 29: Alarms List
Unit/ACT LED
–
PTP 820F
phn-3965_006v002
Page 29-11
Weather conditions,
obstruction in antenna
line of sight, antennae
alignment.
Configured threshold
needs to be adjusted.2.
Check the antennae
alignment and link
planning.
Recalculate the Path Loss
and set the threshold
accordingly.
Check link settings - Tx
Power and Tx Frequency.
Hardware problem.
1651
atpc-override
Alarm
ATPC overridden: Tx level has
been equal to the Max Tx
level for a longer time than
allowed
Warning
Actual transmitted signal
level has been at its
maximum value for
longer than allowed. This
is probably caused by a
configuration error or link
planning error.
Correct the transmission
levels. The alarm will be
cleared only upon
manual clearing.
1697
radio-unit-extreme-
temperature
Alarm
Radio unit extreme
temperature
Warning
Installation conditions.
Defective RFU.
Check installation
conditions.
Verify operation as per
product's specs.
Replace RFU.
1698
radio-unit-low-voltage Alarm
Radio unit input voltage is too
low
Warning
Power supply output too
low.
Power cable to RFU.
Check Power supply.
Replace cable.
1699
radio-unit-high-
voltage
Alarm
Radio unit input voltage is too
high
Warning
Power Supply output too
high.
Check power supply.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...