Chapter 9: TDM Services and Interfaces
Configuring the E1/DS1 Interface
phn-3965_006v002
Page 9-5
Table 98
E1/DS1 Interface Configuration Parameters
Parameter
Definition
Admin
Select
Enable
to enable the port or
Disable
to disable the port.
Timing Mode
Select the clock reference for the outgoing TDM signal from the port.
Options are:
•
Loop
–
The output signal uses the clock of the incoming E1/DS1 lines.
If you select Loop, you must select the clock source reference in the
Recovery Clock Source Reference Port field. By default, each port will
take itself as a reference.
•
Absolute
–
All ports are synchronized to a single common clock,
which you select in the Absolute Clock Reference field.
•
Clock Recovery
–
Adaptive Clock Recovery. Clock information is
recovered on the egress path. Extra information may be located in an
RTP header that can be used to correct frequency offsets.
If you select
Clock Recovery
, you must select the clock source reference
in the
Recovery Clock Source Reference Port
field.
Absolute Clock Reference
If
Timing Mode
is set to
Absolute
, select the clock source reference for
the port. Options are:
•
Front Panel
- An external clock reference from a dedicated front
panel clock interface. This can be:
o
An E1/DS1 line, or
o
A Digital 2.048MHz/1.544MHz input
•
System Reference Clock
If
Timing Mode
is set to
Loop
or
Clock Recovery
, select
None
.
Recovery Clock Source
Reference Port
If
Timing Mode
is set to
Loop
or
Clock Recovery
, select the clock source
reference for the port. Options are 1-16.
By default, each port will take itself as a reference. Select a different port
only if more than 16 clock domains are being used.
If
Timing Mode
is set to
Absolute
, this field must be set to 0.
TDM Signal Line Type
Select the line type of this port. Options are:
•
Unframed
•
E1 (reserved for future use)
•
E1-CRC (reserved for future use)
•
E1-MF (reserved for future use)
•
E1-MF-CRC (reserved for future use)
•
DS1-D4 (reserved for future use)
•
DS1-ESF (reserved for future use)
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...