Chapter 24: Alarm Management and Troubleshooting (CLI)
Performing Diagnostics (CLI)
phn-3965_006v002
Page 24-23
Parameter
Input Type
Permitted Values
Description
ccm-enabled
Variable
true
false
true
–
CCM messages are enabled on the MEP.
false
–
CCM messages are disabled on the MEP.
ccm-ltm-
priority
Number
0-7
The p-bit included in CCMs sent by this MEP.
mep-active
Variable
true
false
true
–
The MEP is Active.
false
–
The MEP is Inactive.
Displaying MEP and Remote MEP Attributes (CLI)
To display the attributes of a specific MEP, enter the following command in root view:
root> ethernet soam mep configuration general show meg-id <meg-id <meg-
id> mep-id <mep-id>
For example:
To display a list of remote MEPs (RMEPs) and their parameters per MEG and local MEP, enter the following
command in root view:
root> ethernet soam mep rmep list show meg-id <meg-id <meg-id> mep-id
<mep-id>
For example: