Chapter 10: Synchronization
Configuring 1588 Boundary Clock
phn-3965_006v002
Page 10-16
2.
In the
Priority 2
field, you can select a value between 0 and 255. The default value is 128. The Priority 2 value
is one of the factors used by the BMCA to determine the grandmaster. The
PTP 820’s
Boundary Clock node
advertises this value when it is not locked on an external grandmaster.
3.
In the
Domain Number
field, you can select a value between 24 and 43. The default value is 24.
4.
In the
Local Priority
field, you can select a value between 1 and 255. The default value is 128. The Local
Priority value is taken into account when two identical announce messages are received by at least two
different ports. In such a case, the Boundary Clock mechanism selects the slave port based on the best
(lowest) Local Priority.
5.
In the
Max Step removed
field, you can select the maximum number of PTP clocks traversed from the
grandmaster to the slave clock in the local PTP 820 Boundary Clock node. The value range is 1-255. The
default value is 255. If the defined number is exceeded, packets from this grandmaster candidate are
discarded and the grandmaster will not be eligible for use by the Boundary Clock node.
6.
To implement your changes, click
Apply
.
The following
Table
lists and describes the read-only Boundary Clock default parameters.
Table 115
Boundary Clock Default Parameters
Parameter
Definition
Two Step
Indicates whether the Boundary Clock node is operating in two-step
mode. In PTP 820, this is always set to
Yes
.
Clock Identity
Identifies the system clock.
Number of Ports
Displays the number of ports on the unit on which Boundary Clock is
enabled. The maximum is 4 per PTP 820 unit.
Clock Class
One of the elements of the clock quality, as defined in IEEE-1588.
Clock Accuracy
One of the elements of the clock quality, as defined in IEEE-1588.
Offset Scaled Log Variance
One of the elements of the clock quality, as defined in IEEE-1588.
Slave Only
Indicates whether the Boundary Clock node is operating in slave
mode only. In PTP 820, this is always set to
No
.
Priority 1
Always displays 128.
Displaying the Boundary Clock Advanced Parameters
To display and set the Boundary Clock advanced parameters:
1.
Select
Sync > 1588 > Boundary Clock > Clock Parameters > Advanced
. The 1588 Boundary Clock
–
Clock
Advanced Parameters page opens.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...