Chapter 24: Alarm Management and Troubleshooting (CLI)
Disabling Alarms and Events (CLI)
phn-3965_006v002
Page 24-8
Disabling Alarms and Events (CLI)
You can choose to disable selected alarms and events. Any alarm or event can be disabled, so that no indication of the alarm is
displayed, and no traps are sent for the alarm.
If you disable an alarm that is currently raised, the alarm is treated as if it has been cleared. If an alarm that has been disabled is
enabled while it is in a raised state, the alarm is treated as if it has just been raised when it is enabled.
If a timeout for trap generation is configured, and a disabled alarm is enabled while the alarm is raised, the timeout count
begins to run when the alarm is enabled. If an alarm is disabled while raised, the timeout count begins to run upon disabling the
alarm, and an alarm cleared trap is sent when the timeout expires.
To disable an alarm or event, enter the following command in root view:
root> platform status alarm-management set alarm-id <alarm ID> admin disable
To enable an alarm or event, enter the following command in root view:
root> platform status alarm-management set alarm-id <alarm ID> admin enable
To display a list of all disabled alarms and events, and their attributes, enter the following command in root view:
root> platform status alarm-management show all admin disable attributes
To display a list of all enabled alarms and events and their attributes, enter the following command in root view:
root> platform status alarm-management show all admin enable attributes
To enable all alarms and events, enter the following command in root view:
root> platform status alarm-management set all admin default
The alarm status commands
platform status alarm-management show alarm-id all
and
platform status alarm-management
show alarm-id <alarm-id> attributes
display alarms, even if they are disabled. The Alarm Admin column in the output displays
whether the alarm or event is enabled or disabled.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...