Chapter 24: Alarm Management and Troubleshooting (CLI)
Viewing Current Alarms (CLI)
phn-3965_006v002
Page 24-3
Viewing Current Alarms (CLI)
To display all alarms currently raised on the unit, enter the following command in root view:
root> platform status current-alarm show module unit
To display the most severe alarm currently raised in the unit, enter the following command in root view:
root> platform status current-alarm show most-severe-alarm module unit
For example:
root> platform status current-alarm show most-severe-alarm module slot
all
Most Severe Alarm Table:
========================
Slot Severity
===========================
1 critical
64 cleared
68 cleared
root>
Modules are identified as follows:
•
1
–
Fixed Interfaces
•
64
–
LAG
•
66
–
Multi-Carrier ABC
•
67
–
XPIC
•
68
–
HSB Radio Protection
To display the most severe alarm currently raised in the unit, enter the following command in root view:
root> platform status current-alarm show most-severe-alarm module unit