Chapter 1: Introduction
RFU Overview
phn-3965_006v002
Page 1-18
IDU-RFU Connection and Power Supply for PTP 820F
An RFU-D, RFU-D-HP, RFU-E, and RFU-S can be connected to anPTP 820F via a standard CAT-5e or preferably CAT-
6/6a cable, with RJ-45 connectors on the RFU and an RJ-45 connector on thePTP 820F. They can also be connected
to the PTP 820F over optical fiber cables via the optical (SFP) RFU connection on the PTP 820F.
For an RFU-D, RFU-E, or RFU-S connecting to an electrical RFU interface, the cable can carry both the data and the
DC power required for the RFU. For configuration instructions, see
Configuring the IDU-RFU Connection (PTP 820F
For an RFU-D, RFU-E, or RFU-S connecting to an optical RFU interface, and for an RFU-D-HP connecting to either an
electrical or an optical RFU interface, an external DC power cable is required to supply power to the RFU.
Table 5
IDU-RFU Cable connection for PTP 820F
RFU
Interface
Cable Type
Maximum Length
6-11 GHz
13-42 GHz
RFU-D
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
50m
130m
CAT-6a (22 AWG)
100m
150m
DC Power
DC (18 AWG)
100m
DC (12 AWG)
101m-300m
RFU-E/RFU-S
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
150m
CAT-6a (22 AWG)
150m
DC Power
DC (18 AWG)
150m
DC (14 AWG)
151m-300m
RFU-D-HP
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
150m
CAT-6a (22 AWG)
150m
DC Power
DC (14 AWG)
100m
DC (10 AWG)
101m-200m
DC (8 AWG)
201m-300m
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...