Managing Remote Access Concentrators Using Annex Manager
Appendix A RAC Parameters
A-100
time_server_addr
lists the IP address that a RAC queries for time service. You can enter:
•
A loopback address (127.0.0.1) to disable time service queries.
•
A host address to send queries to a specific host.
•
A broadcast address to send queries to a specific network or
networks instead of sending a general broadcast to all networks.
•
0.0.0.0
to direct the RAC to query the boot host.
timezone_minuteswest
defines the time zone in which the RAC resides. You can enter a positive number
of minutes for time zones west of Greenwich Mean Time (GMT) or a negative
number for time zones east of GMT. For example, you would enter
300
for U.S.
Eastern Standard Time, which is five hours west of GMT, or -60 for Paris, which
is one hour east of GMT.
tmux_delay
provides the maximum number of milliseconds during which small packets can
accumulate to form larger packets. When the time expires, the multiplexed packet
is sent. Entering
0
sets this parameter to 20 (the Annex Manager default value).
Type
RAC
Values
loopback address, host address, broadcast address, 0.0.0.0
Default
0.0.0.0
Lists
RAC Only, Time of Day
Type
RAC
Values
positive or negative number of minutes
Default
300
Lists
RAC Only, Time of Day
Type
RAC
Values
0 through 255
Default
20
Lists
RAC Only, TMux
Summary of Contents for 5391
Page 6: ...Managing Remote Access Concentrators Using Annex Manager vi ...
Page 16: ...Managing Remote Access Concentrators Using Annex Manager About This Guide xvi ...
Page 190: ...Managing Remote Access Concentrators Using Annex Manager Chapter 9 Configuring SNMP Traps 9 4 ...
Page 296: ...Managing Remote Access Concentrators Using Annex Manager Appendix A RAC Parameters A 106 ...
Page 342: ...Managing Remote Access Concentrators Using Annex Manager Appendix D Help Reference D 8 ...