Managing Remote Access Concentrators Using Annex Manager
Appendix A RAC Parameters
A-50
inactivity_timer
specifies the number of minutes that a port can remain inactive. If the timer
expires, the RAC terminates all sessions and resets the port. You can use
input_is_activity
and
output_is_activity
to define activity as input to the port or output
from the port. If you set these parameters to
disabled
, the timer runs independent
of activity. To reset a port regardless of any activity, enter a number of minutes
here, set
input_is_activity
and
output_is_activity
to
disabled
and set
port_type
to
dialin
.
inet_addr
defines the RAC IP address. This 32-bit address contains four 8-bit fields
separated by periods. Each field contains a number ranging from 0 to 255 or a
hexadecimal number. The IP address always displays in decimal notation.
input_buffer_size
provides the number of 256-byte blocks allocated to receive input characters for
a port.
Type
Async
Values
0 to 255 minutes
Default
0 (timer disabled)
Lists
Async Port, Idle Timer, Modem, Modem Internal
Type
RAC
Values
For each field: 0 to 255 or hexadecimal
Default
n/a
Lists
RAC Only, Basic RAC
Type
Async
Values
1 to 255
Default
1
Lists
Async Port, Flow Control
Summary of Contents for 5391
Page 6: ...Managing Remote Access Concentrators Using Annex Manager vi ...
Page 16: ...Managing Remote Access Concentrators Using Annex Manager About This Guide xvi ...
Page 190: ...Managing Remote Access Concentrators Using Annex Manager Chapter 9 Configuring SNMP Traps 9 4 ...
Page 296: ...Managing Remote Access Concentrators Using Annex Manager Appendix A RAC Parameters A 106 ...
Page 342: ...Managing Remote Access Concentrators Using Annex Manager Appendix D Help Reference D 8 ...