Managing Remote Access Concentrators Using Annex Manager
Chapter 5 Booting and Resetting RACs
5-4
6.
Click
OK
to activate the boot or Cancel to return to the
Boot
window.
When you click
OK
, Annex Manager notifies the console and all
terminals connected to the RACs you selected about the boot. Boot
command messages are described on page 5-6.
When the boot takes place, a warning window appears. This
window lists the RACs where the boot transmission was successful
and, if necessary, lists RACs where the boot transmission was
unsuccessful.
If you boot an active RAC, its status in the main
window list changes to
NOT REACHABLE
. In fact,
although the RAC is not available while boot
processing takes place, a successful boot does restore
the RAC on your network. Use
Verify Annex State
to
restore the display.
The Boot Window
The
Boot
window radio buttons define the type of
boot
operation. Text
fields control the
Boot
command addresses, source, time, image, and
message to users. The Annex Manager standard push buttons activate the
command. This section describes each window element.
You can choose one of the following
Boot Option
buttons:
•
Immediate
boots RACs as soon as you activate the command.
•
Delayed
accepts a
Boot Time
at which the boot occurs. You can
enter more than one delayed request. However, if you enter a
second request for a time earlier than an existing request, the
selected RACs boot at the earlier time and all other existing
boot requests are deleted.
•
Dump
saves the current image to the address you enter in the
Pref Dump Addr
field.
•
Diagnostic
places a RAC in test mode and begins diagnostic
tests. When these tests end, the RAC is in ROM Monitor mode
and cannot respond to Annex Manager requests until you boot
it.
Summary of Contents for 5391
Page 6: ...Managing Remote Access Concentrators Using Annex Manager vi ...
Page 16: ...Managing Remote Access Concentrators Using Annex Manager About This Guide xvi ...
Page 190: ...Managing Remote Access Concentrators Using Annex Manager Chapter 9 Configuring SNMP Traps 9 4 ...
Page 296: ...Managing Remote Access Concentrators Using Annex Manager Appendix A RAC Parameters A 106 ...
Page 342: ...Managing Remote Access Concentrators Using Annex Manager Appendix D Help Reference D 8 ...