Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
212
4.4
1)
Speed_1
2)
Speed_2
52.2
Mean speed 1
Display of the determined speeds while the drive is being operated at constant speed
Speed_1.
52.3
Mean speed 2
Display of the determined speeds while the drive is being operated at constant speed
Speed_2.
14
End
15
Not used
16
Error: Time for speed Speed_1
1)
less than 2 seconds
17
Error: Time for speed Speed_2
2)
less than 2 seconds
18
Error: Time for acceleration less than 0.1 seconds
19
Error: Time for braking less than 0.1 seconds
20
Error: Time for Speed_1
1)
or Speed_2
2)
or acceleration or braking phases
greater than 120 seconds
21
Error: Set speed Speed_1 or Speed_2 too low, < 10 degrees/s
22
Error: Determined value of Ks would be negative because acceleration value
too low
23
Error: Determined value of Ks would be negative because acceleration value
too low during braking
24
Error: Speed deviation too great (>5%)
25
Error: Incorrect acceleration sign during acceleration or braking
26
Error: Set acceleration not equal to ZERO at constant speed
27
Error at the Ks measurement with FFT module
40
Start Ks measurement with FFT module
41
Wait until the FFT module is available
42
Measurement using the FFT module is active
43
Calculation of the speed controller parameters
Value
Meaning