Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
649
4
Figure 212:
ProDrive - Resulting signal of the motor diagnosis
If the resulting signal complies with the sine of about two cycles, then it can be assumed
that the notch position search operates reliable with the injection.
4.8.10.5 Parameter overview
Functional block:
FbInjektion [133]
Parameter 19.52, refer to
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
133.1
Mode sensorless
UINT
0
0xffff
0
1:1
X
133.2
Injection frequency 1
FLOAT
0
4000.0
1000.0
Hz
1:1
X
133.3
Injection amplitude 1
FLOAT
1
400.0
100.0
V
1:1
X
133.4
Bandpass bandwidth
FLOAT
1
500.0
50.0
Hz
1:1
X
133.5
Injection Kp
FLOAT
-1.10 1.10 80
1/s
1:1
X
133.6
Injection frequency 2
FLOAT
0
1000.0
250.0
Hz
1:1
X
133.7
Injection amplitude 2
FLOAT
1
400.0
280.0
V
1:1
X
133.9
2nd harmonic rate
FLOAT
0
100.0
0
%
1:1
X
133.10
2nd harmonic min.rate
FLOAT
0
100
5
%
1:1
X
133.11
Carrier current Id
FLOAT
-1.10 1.10 0
A
1:1
X
133.12
Carrier current Iq
FLOAT
-1.10 1.10 0
A
1:1
X
133.14
Status motor observer
DINT
0
10
0
1:1
X
133.15
Injection Tn
FLOAT
0.1
1e10
4
ms
1:1
X