Error detection
The illumination of the red LEDs H14 (axis 1) and H24 (axis 2) on the front of the housing
signals the occurrence of a error status.
A max. of 3 LEDs
are illuminated.
Essentially, the lowest red LEDs H14 and H24 "Error" are of significance here.
5.4
Error handling
Error messages, which can also be considered error lists, are the basis of the error han-
dling.
5.4.1
Error reset
If the red error LED is illuminated, at least one error is present.
Error reset cause all error messages to be reset. Individual resetting of errors is not pos-
sible. A reset causes deletion of the errors, if deletion was possible on account of the error
circumstances.
There are two methods of resetting an error:
m
By means of write access to the control word
m
Via a digital input
For further information on the subject of error reset, see "Instruction Manual
b maXX
3000“.
NOTE!
In case of warnings or errors without error reactions, the LEDs H14 or H24
blink
"Er-
ror". Only error messages with error reaction will be signalized by
constant lighting
up
.
NOTE!
The device is shipped with predefined error reactions. With regard to the error mes-
sages identified with "depending on the setting" in the "Reaction" column, the de-
vice's error reaction can be adjusted. Errors that, due to safety reasons, have an
immediate pulse inhibit as a consequence, may not be changed.