![Baumuller b maXX BM2500 Operating Manual Download Page 455](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400455.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
455
4
18.10
Position controller status
Status of the position controller.
18.11
w1 position set value
Display of the current position set value in degrees.
18.12
x1 position actual value
Display of the current actual position in degrees.
18.13
e1 position controller error
Current position error in degrees.
4
0: Single PT
1
filter for speed actual value
1: Bilinear PT
1
filter for speed actual value
5
Reserved
6
0: I/f operation at controlled stop
1: U/f operation at controlled stop
8 … 7
Reserved
9
Reversal of rotation:
This bit internally changes the rotary field, encoder evaluation and the
notch position and changes the direction if the set value setting is the
same.
Notice!
With incremental encoders the notch position search must be
executed once more!
31 … 10
Reserved
Bit
Meaning
Bit
Meaning
9 … 0
Reserved
10
Position encoder is referenced
11
Reserved
12
Position controller has reached the set value
31 … 13
Reserved