Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
570
4.8
Bit no. Meaning
Online
change
0
Synchronization set to actual speed with Changeover operating
mode:
0: No synchronization
1: Synchronization ON
1 … 2
Adjusting the speed profile:
00: Trapezoidal
01: S-Curve
10: Reserved
11: Reserved
X
3
Reserved
4
Adjustable response when the new target position is outside of the
software end switch
0: Move to software end switch position
1: Do not report movements and errors
5
Adjustable response with movement in hardware end switch:
0: Braking to N=0
1: Braking to N=0 and report error
6
Starting response with controller activation for relative positioning:
0: After activation, a positive edge is required in the Start bit
1: After activation, a start will occur immediately with set Start bit
7
0: No homing required for positioning
1: Homing required before positioning can occur
8
Controlling the Positioning through
0: "New set value" (
Control word Bit 4 New set value)
1: "Start Positioning" (
Control word Bit 11 Start Position-
ing
9
Reserved
10
Automatic start when changing the positioning record
0: No automatic start with set change
1: With the Change positioning set, the new set will automatically
transferred and started when the Start bit is set (
Con-
trol word Bit 4 or 11).
11
Interpretation of the control word with control through "New set
value"
0: Compatible with b maXX 4400
1: According to IEC61800-7-201
12
Negative directional block
1: Block negative direction
X
13
Positive directional block
1: Block positive direction
X
14
Positioning time monitoring ON
0: OFF
1: Active (monitoring time is adjusted in Parameter
Posi-
tioning timeout ON)