Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
262
4.4
124.3
Status
Status of the measuring encoder.
Bit
Meaning
Encoder 1
0
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP1 positive edge
1
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP1 negative edge
2
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP2 positive edge
3
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP2 negative edge
4
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger Zero
Pulse positive edge
5
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger Zero
Pulse negative edge
6 ... 15
Reserved
Bit
Meaning
0
Measured value storage Measurement Channel "Encoder 1 with Trigger
digital input TP1 positive edge":
0: Switched off
1: Switched on
1
Measured value storage Measurement Channel "Encoder 1 with Trigger
digital input TP1 negative edge":
0: Switched off
1: Switched on
2
Measured value storage Measurement Channel "Encoder 1 with Trigger
digital input TP2 positive edge":
0: Switched off
1: Switched on
3
Measured value storage Measurement Channel "Encoder 1 with Trigger
digital input TP2 negative edge":
0: Switched off
1: Switched on