Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
650
4.8
4.8.10.6 Description of the Parameters
133.1
Mode sensorless
Here is set, if the motor shall be operated in the lower speed range with the injection pro-
cedure or if it shall be operated controlled. It also can be set, if, at first, a notch position
moving shall be executed and also if a synchronization shall take place.
133.16
Voltage model Tn
FLOAT
0.01
1e5
4
ms
1:1
X
133.17
Current dependent correction FLOAT
-1000
1000
1
1:1
X
133.18
Estimated speed
FLOAT
-1e10
1e10
0
Grad/s 1:1
X
133.19
Speed threshold
FLOAT
5
6000000
1200
Grad/s 1:1
X
133.20
Speed filter
FLOAT
0
10000
2
ms
1:1
X
133.22
Current
FLOAT
0
100000
0.5
A
1:1
X
X
133.25
Time for notch position
FLOAT
0.1
5
3
s
1:1
X
133.28
Minimum speed torque moni-
toring
FLOAT
0
10000
60
Grad/s 1:1
X
133.30
Deviation voltage model
FLOAT
-10000
10000
0
1:1
133.31
Deviation injection
FLOAT
-10000
10000
0
1:1
133.41
Anisotropy
FLOAT
0
50000000
0
A
1:1
X
133.51
Saliency ratio
FLOAT
0
1
0.1
1:1
X
133.55
Damping factor
FLOAT
0
1e6
0
1:1
X
X
133.58
Time constant fast damping
filter
FLOAT
0
10000
1
ms
1:1
X
133.59
Time constant slow damping
filter
FLOAT
0
100
1
s
1:1
X
Bit
Meaning
1 ... 0
0: Injection procedure
1: Controlled with notch position
3: Controlled without notch position
2
1: Synchronize
3
Reserved
4
Constant current in controlled operation
0: Current is constant
1: Maximum current at acceleration
5
Reserved
6
1: No dead time compensation during notch position search
7
Reserved
8
1: Switch off of the dLi/dt terms
9
Fine adjustment of the dead time compensation
15 ... 10
Reserved