![Baumuller b maXX BM2500 Operating Manual Download Page 708](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400708.webp)
Diagnosis
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
708
4.9
4.9.3.2 Description of the Parameters
104.1
Command
This parameter can be used to switch the FFT function on or off.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
104.1
Command
UDINT
0
4
0
1:1
X
104.2
Status
UDINT
0
41
0
1:1
X
104.3
Signal input 1 source Pxxx
UDINT
0
0xFFFFFFFF 0
1:1
X
104.4
Signal input 2 source Pxxx
UDINT
0
0xFFFFFFFF 0
1:1
X
104.5
Signal input 1 / 2 axis
UINT
0
0x11
0
1:1
X
104.6
Signal out target-Pxxx
UDINT
0
0xFFFFFFFF 0
ID
1:1
X
104.7
FFT mode
UDINT
0
0xFFFF
0
1:1
X
X
104.8
FFT info
DINT
0
12
0
1:1
104.9
FFT length
DINT
64
4096
4096
1:1
X
104.10
FFT windowing
UINT
0
5
1
1:1
X
104.11
Average number setup
DINT
0
20000
16
1:1
X
104.12
Signal out amplitude
FLOAT
-1e+9
1e+9
0
1:1
X
104.13
Signal output offset
FLOAT
-1e+9
1e+9
0.00
1:1
X
104.14
Frequency for sinus genera-
tor
FLOAT
0
8000
0
Hz
1:1
X
104.15
Signal out
FLOAT
-1e+9
1e+9
0
1:1
X
104.16
Input signal 1
FLOAT
-1e+9
1e+9
0.00
1:1
X
104.17
Input signal 2
FLOAT
-1e+9
1e+9
0.00
1:1
X
104.18
Actual average
DINT
0
20000
0
1:1
X
104.19
Max. frequency
FLOAT
0.00 8000
2000
Hz
1:1
X
104.20
Frequency resolution
FLOAT
0.00 62.5
9.765625e-01
Hz
1:1
X
104.21
FFT data
FLOAT
0
0
0
1:1
X
104.22
Prbs register length
UINT
0
19
19
1:1
104.23
Prbs register clock
UINT
1
0xFFFF
1
1:1
FFT Command Meaning
0
Stop
1
Run