Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
152
4.4
4.4.4.5 Description of the Lh-characteristic parameters
123.39
Speed for Lh identification
Speed (in % of the nominal speed), at which the Lh identification is executed.
146.17
State Lh identification
146.19
Ramp-up time nominal speed
Ramp-up time for controlled acceleration/deceleration to nominal speed/speed = 0 due to
determine the main inductivity characteristic.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
123.39
Speed for Lh identification
FLOAT
0
0xFFFFFFFF 30
%
1:1
X
146.17
State Lh identification
UINT
0
10
0
1:1
X
146.19
Rising time nominal speed
FLOAT
1
1000
10
s
1:1
X
Value
Description
0
Inactive
1
Initialization
2
Acceleration of nominal speed with 1.1 * magnetizing current
3
To build up
4
Wait until current and voltage are constant
5
Measuring the voltages
6
Braking to 0
7
Calculating the inductance
8
Motor control entry in table
9
Completed
10
Completed