Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
697
4
6.43
Motor I
2
t monitoring mode
The accordant implementation to calculate the l
2
t value of the motor must be selected.
Generally, the parameter is assigned to zero (speed-dependent monitoring is deactivated
and the monitoring of the apparent current is activated). See
1)
These methods require valid motor data. The parameter
>
6.43
<
does not accept the entered value if there
is no valid motor data.
2)
Combinable with all motor l
2
t modes
6.46
Motor I
2
t derating factors
Includes the derating factors in the elements 6.46[0] and 6.46[1] in percent relating to the
rated current to interpolate the current limit curve for standardized asynchronous ma-
chines without forced ventilation. Thereby, the element in 6.46 [0] defines the maximum
continuous current in the standstill operating point and 6.46 [1] defines the operating point
at the half rated speed.
In general, both derating factors provide a value of 100% which accords to the speed-in-
dependent standardized solution of the l
2
t monitoring (refer to
from page 731). The minimum value corresponds to 10%.
6.47
Operation grade real power
The real power limit load is displayed.
Is evaluated at single-phased devices, only in which the maximum real power limit was
parameterized in the power unit characteristics as well.
Bit
Meaning
2 ... 0
Value
Speed dependent modes
0
Deactivated
1
Continuous current limit identification by current-supporting
points and interpolation
1)
2
Continuous current limit identification by approximation of core
losses
1)
3
Derating identification of machines having no separately ventila-
tion
1)
4 to 8
Reserved
3
Current monitoring type:
2)
0: Apparent current
1: Single phases
15 ....4
Reserved