Diagnosis
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
700
4.9
4.9.2
Oscilloscope function
The b maXX
®
controllers offers an integrated oscilloscope function for quick and easy
commissioning.
Range of oscilloscope function:
4.9.2.1 Parameter overview
Functional block:
FbRsp [101]
Number of channels:
8
Sampling time:
62.5 µs to 100 s
Recording:
triggered or not triggered
Triggering:
m
through internal status changes,
m
Size change or
m
external digital or analog inputs
Number of Triggers:
1
Trigger time in relation to
memory depth:
Recording after-running period parameterizable
(which means recording with or without prior
history related to the trigger event)
Trigger sources:
m
Digital signals (selection of relevant bits
through bit masks is possible) e. g.:
n
Status change
n
Error or warning events
n
external digital inputs
m
analog signals
n
Target or actual values
n
Analog inputs
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
or
t
Cyclic
W
rite
101.1
Status
INT
0
5
0
1:1
X
101.2
Command
INT
0
7
0
1:1
X
101.3
Channel 0 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X
101.4
Channel 1 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X
101.5
Channel 2 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X
101.6
Channel 3 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X
101.7
Channel 4 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X
101.8
Channel 5 source parameter
id
UDINT
0
4294967295
0
ID
1:1
X