Controllers
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
522
4.7
155.1
Mode
Configuration of the controller adaption function:
155.2
State
State of the controller adaption function.
Bit
Meaning
0
Direct speed controller adaption (switch)
0: Switch off
1. Switch on
2 … 1
Direct speed controller adaption (D-part mode)
00: T
d
is not adapted
01: T
d
is 0 for n > n
1
(lower threshold)
10: T
d
is 0 for n > n
3
(upper threshold)
11: Reserved
3
Direct current controller adaption
0: Switch off
1: Switch on
4
Ks adaption cyclic
0: Switch off
1: Switch on
5
Reserved
7 ... 6
Direct speed controller adaption
Speed controller adaption according to:
00: Actual value
01: Set value
10: Speed feedforward
11: Parameter for free use
15 … 8
Reserved
Bit no.
Meaning
0
Direct speed controller adaption:
0: inactive
1: active
2 ... 1
Direct speed controller adaption (D-part mode)
00: T
d
is not adapted
01: T
d
is 0 for n > n
1
(lower threshold)
10: T
d
is 0 for n > n
3
(upper threshold)
11: Reserved
3
Direct current controller adaption
0: inactive
1: active