Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
179
4
106.3
Encoder options
Options for encoder evaluation.
2
0: Encoder initialization not active
1: Encoder initialization active
15 ... 3
Reserved
Bit
Description
Bit
Meaning
Remark
0
Inversion of the encoder
evaluation
0: Not inverted
1: Inverted (mounted with different direction
of revolution)
1
Automatic signal correction 0: Switched off
1: Activated. An automatic correction of
amplitude and offset of the sine-cosine
signals is carried out.
2
Inversion of the serial read
position
0: Not inverted
1: Inverted (the serial read out absolute posi-
tion will be inverted)
3
Initialization of HIPER-
FACE
®
-encoder with
assignment to analog sig-
nal
0: Initialization with the digitally read position
only
1: Initialization with digitally read position and
analog signals (better initialization accu-
racy, assignment of digital position refer-
ring to analog tracks must be available)
4
Start of the automatic static
encoder error correction
5
Identification of unbalance
6
Activation of unbalance
compensation
7
Consideration of the
encoder’s range at addition
of the M0 Offset
0: The M0 Offset will be added without con-
sideration of the range which is clearly dis-
tinguishable by the encoder
1: The range which is clearly distinguishable
by the encoder will be considered at the
addition of the M0 Offset (e. g. overflow at
4096 revolutions)
9 ... 8
Reserved