Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
121
4
m
Load factor mode ASM-IsdMax
ASM only:
bit 1 = 1 (bit 3 = 0 from FW 01.13 of the controller):
I
max aux
= "Max. drive current actual value"
I
sd aux
= "Limit magnetizing current"
m
Current mode
(from controller FW 01.13 onwards)
bit 3 = 1 (independent of bit 1 and the motor type)
I
max aux
= "Max. drive current"
I
sd aux
= 0,
or I
sq max ref
*
>
19.8
<
= "Max. drive current"
Figure 69:
Modes of the "Max. torque current 19.8 at the synchronous motor
a) Field current dependence (external total current limit is not assumed).
b) External total current limit dependence (field weakening is not assumed).
5000_0349_rev01_int