Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
119
4
Remark:
Values 2 to 43 are only displayed when a pole position search is active (Actual Operating
Mode
= -1).
For the other drive operating modes, the status is either 0 or 1.
19.5
Max. drive current actual value
Shows the currently effective limit of the apparent current. It influences the limit of the cur-
rent torque as well as of the field current. The parameter accords to the minimum value
between the "maximum total current of the drive"
and the "External limitation of
the maximum total current"
.
19.6
Max. drive current
Settable limitation of the apparent current of the drive influences the limitation from the
current torque as well as from the field current.
The maximum total current of the drive is limited by the "Power unit peak current"
"Max. drive current" [
>
19.6
<
]
"Power unit peak current" [
39 ... 22
Reserved
40
Pole position offset will be entered in Parameter
41
Pole position offset will be stored in the encoder
42
Slow reduction of current after completion of the pole position search
43
Pole position search completed successfully
Value
Meaning
NOTE!
m
The apparent current limit of the drive can automatically be reduced furthermore,
for example by the PU overload monitoring or the phase fail (see "bit bar of external
current limit"
and "External limiting max. drive current"
.9 and the
value of the parameter
>
19.6
<
is not changed. The current acting limit of the ap-
parent current is displayed in the " Maximum available total current"
.
m
The "Max. drive current"
>
19.6
<
is the scaling size of the standardized current pa-
(current threshold motoric/generator; operation mode
U-f characteristic).