Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
195
4
137.29
Position format
The parameter is set at EnDat
- and Hiperface
-encoders only.
It displays the resolution of the digital position value, which is read out of the encoder. The
parameter corresponds to the angle resolution at singleturn encoders. The sum of the
resolution of angle and revolutions is displayed at multiturn encoders.
The total resolution of the position value is displayed at length measuring systems.
137.30
Instruction set
The parameter is only valid for EnDat
®
encoders.
It displays the supported instruction set as well as type specific information of the con-
nected encoder.
Only measuring devices with Bit 0 = 1 and Bit 1 = 0 support the functions of EnDat
®
ver-
sion greater or equal 2.2.
137.31
Number of bits revolution counter
The parameter is set at EnDat
- and Hiperface
-encoders only.
It displays the resolution of the digital position value (number of bits) in the area of revo-
lution of multiturn encoders.
The parameter displays 0 at singleturn encoders and length measuring devices.
137.32
Angle bits
The parameter is set at EnDat
- and Hiperface
-encoders only.
It displays the resolution of the digital position value (number of bits) in the area of angle
at encoders or angle measuring devices.
Bit
Meaning
1 ... 0
01: Instruction set type 2.2 is supported
3 ... 2
01: safety relevant applications are supported
5 ... 4
01: Mode command "Measuring device receives comm. command" is
supported
7 ... 6
01: Shutdown of instruction set type 2.2 is supported
Residual
Reserved