4.6
168.6
Increment
Setting the amount of output value change.
If e.g. the value 1% is set, the ramp function generator parameter
Input 16 bit
increases by 1% at each clicking of the "Motor potent" button up to the maximum
upper limit
in the edge sensitive mode.
Increment
int
[%] / 100% * Max
where Max
= 16384 = internal standardization of 100% of the ramp function
generator parameter
Input 16 bit
Increment
int