![Baumuller b maXX BM2500 Operating Manual Download Page 706](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400706.webp)
Diagnosis
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
706
4.9
101.22
Measure time
Display of the time used by the Scope Buffer module in real time (Interrupt). This time de-
pends on the number of channels and axes.
101.23
Scope buffer
Two-dimensional array for Type FLOAT32 scope buffer data.
The 1st dimension corresponds with the channels,
Channel 0 is reserved,
Channel 1 ….Channel 8 correspond with the recording channels,
Channel 9 corresponds with the trigger channel
The 2nd dimension corresponds with the discrete distance intervals. The array is indicat-
ed with 200 elements; however, this limit is dynamic depending on the number of active
recorded channels.
The data type of the array is FLOAT32. Depending on the data type of the recorded chan-
nel, the raw data is stored in the memory in the format of the source data type (always
stored in 4 bytes).
The corresponding axis can be addressed through the SubDevice Index. The internal
controller ring buffer is organized 3-dimensional accordingly.
If no data is present in the ring buffer, the Read command response with error code:
RC_ERR_RSP_NODATA (1305)
If an attempt is made to read data from the buffer during recording, the Read command
responds with error code: RC_ERR_RSP_NOREAD (1304)
Index 0 of the 2nd dimension points to the most current value.
101.24
Task number
Display in which the ring buffer recording is carried out:
1:
62.5 µs time dials
2:
1 ms RT1