47.55
SM Phi error
Display of the identified field angle deviation of the PMSM.
47.65
Current controller cycle time
Display parameter for the cycle time of the current controller. The cycle time results from
the setting of
PWM Frequency.
The current controller cycle time must not exceed the
RT0-Cycle time. This is mon-
itored and as the case may be the error 501 will be triggered which inhibits enabling of
the drive.
47.70
Deadtime voltage uAlpha
The deadtime voltage uAlpha, which is determined due to the current actual values.
47.71
Deadtime voltage uBeta
The deadtime voltage uBeta, which is determined due to the current actual values.
155.11
Low adaption threshold for current controller
Current Iq, from which the current controller adaption starts.
155.12
High adaption threshold for current controller
Current Iq, from which the minimum current controller gain acts.
155.13
Kp current controller adaption
This percentaged value describes the real acting part of the proportional gain of both cur-
rent controllers at a current Iq above the high adaption threshold for the current controller