![Baumuller b maXX BM2500 Operating Manual Download Page 423](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400423.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
423
4
4.6.4.2 Description of the Parameters
148.1
Mode
Configuration of error reaction return motion.
A change of the bit 0 mode during a continuous return motion positioning does not affect
the present return motion positioning.
148.2
Status
Status of error reaction return motion
Bit
Meaning
0
Interpretation of the return motion target position (related to
posi-
tion actual value):
0:Absolute (short distance)
1:Relative to the current position
1
Enabling of return motion function:
0: Return motion enable
1: Return motion inhibit
The return motion is not be started at all or is canceled (drive stops) if bit is
set. A corresponding error message is displayed.
31…2
Reserved
Bit
Meaning
0
0: Return motion positioning is not active
1: Return motion positioning is active
1
0: Target position is not reached
1: Target position is reached, the return motion positioning was stopped cor-
rectly.
This bit will be deleted when upcoming error is reset.
3…2
Reserved
4
1: Return motion positioning can/could not be started or is canceled.
Accumulative bit, for details see bit 8 to 11
7…5
Reserved
8
If bit 4 = 1:
1: Inhibit / abort with
Bit 1 = 1
9
If bit 4 = 1:
1: Abort on the hardware end with pulse inhibit (digital input) or with a more
significant error reaction (pulse inhibit or stop at ramp).