Controllers
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
482
4.7
4.7.2.9 Description of Current Controller Parameters
47.1
Isq set value
Display of the limited Isq set value which is passed directly to the current controller.
47.27
U Alpha set value
FLOAT
-440
440
0.0
V
1:1
X
47.28
U Beta set value
FLOAT
-440
440
0.0
V
1:1
X
47.29
Control value U
FLOAT
0.0
1.0
5.0e-01
1:1
X
47.30
Control value V
FLOAT
0.0
1.0
5.0e-01
1:1
X
47.31
Control value W
FLOAT
0.0
1.0
5.0e-01
1:1
X
47.32
Iu actual value
FLOAT
-10000
10000
0.0
A
1:1.414 X
47.33
Iv actual value
FLOAT
-10000
10000
0.0
A
1:1.414 X
47.34
Iw actual value
FLOAT
-10000
10000
0.0
A
1:1.414 X
47.40
PWM MSVM threshold
UINT
0
100
100
%
1:1
X
47.41
Ualpha after PWM
FLOAT
-440
440
0
V
1:1
X
47.42
Ubeta after PWM
FLOAT
-440
440
0
V
1:1
X
47.43
Uq after PWM
FLOAT
-440
440
0
V
1:1
X
47.44
Ud after PWM
FLOAT
-440
440
0
V
1:1
X
47.45
Rho-RT0
UINT
0
0xFFFF
0
1:1
X
47.46
Delta-Rho in Inc/ I-controller-
clock
INT
-32768
32767
0
1:1
X
47.47
Motor Rho
UINT
0
65535
0
1:1
47.49
Output frequency filtered
FLOAT
-1e9
1e9
0
Hz
2
:1
X
47.50
Dead time compensation
FLOAT
0.0
2.0e+02
0.0
%
1:1
X
47.51
Current controller mode
UINT
0
65535
0
1:1
X
47.52
Iq predicted
FLOAT
-10000
10000
0
A
1:1
X
47.53
Id predicted
FLOAT
-10000
10000
0.0
A
1:1
X
47.54
back emf estimated
FLOAT
-440
440
0
V
1:1
X
47.55
SM Phi error
FLOAT
-180
180
0
Grad
1:1
X
47.65
Current controller cycle time FLOAT
62.50
250.00
62.5
µs
1:1
X
47.70
deadtime voltage ualpha
FLOAT
-440
440
0
V
1:1
X
47.71
deadtime voltage uBeta
FLOAT
-440
440
0
V
1:1
X
155.11
Low adaption threshold for
current controller
FLOAT
0
10000
0
A
1:1
X
155.12
High adaption threshold for
current controller
FLOAT
0
10000
0
A
1:1
X
155.13
Kp current controller adap-
tion
FLOAT
0
100
100
%
1:1
X