Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
187
4
106.61
SSI status
Status of SSI transmission:
106.62
SSI bits angle
Setting of bit numbers to transmit the angle (0 to 31).
106.63
SSI bits revolutions
Setting of bit numbers to transmit revolutions (0 to 31).
106.64
SSI angle
There is a 32 bit value for the SSI angle (singleturn) in increments, which is directly read
by the encoder.
106.65
SSI revolutions
There is a 32 bit value for the SSI revolutions (multiturn), which is directly read by the en-
coder.
Bit
Meaning
0
Transmission activity
0: Transmission is not active
1: Transmission is active
1
Validity of data
0: The encoder data is invalid (parity error)
1: The output data is valid
2
Reserved
3
Parity error
0: No parity error
1: Parity error
31 … 4
Reserved