Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
363
4
4.5.2.3 Organization of the parameters in the data sets
Within the device there are seven separate memory areas for parameters that have the
"Data Set" attribute (DS 1 to DS 7).
In addition there is a "window" which represents the current active data set (DS 0). One
of these seven data sets is always selected active. By writing to Parameter
Ac-
tive Data Set Number, Data Set 1, 2, 3, 4, 5, 6 or 7 can be selected to be active, hence it
is possible to switch between the data sets. In so doing, the window moves from DS 0 to
the memory area of the activated data set.
Example:
Data Set 3 is activated.
The "window" for the active data set addresses Data Set 3.
Figure 127:
Active data set
Basically, only data from the
active data set
(DS 0) can be accessed via external option
modules or Fieldbuses.