Management
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
344
4.5
m
Bit 7: Device control command "Error reset"
A change to this bit from 0 to 1 is required for the command.
m
Bit 8: Hold
n
Synchronous operation (Operating mode -5)
0: Continue synchronous operation
1: Disconnect slave axis from master axis and hold
n
Position control (Operating mode -4):
0: Continue position control
1: Hold axis with
stop delay (FbPosCommonData)
n
Target Position Setting (Operating mode 1):
0: Continue positioning
1: Hold axis with positioning delay
n
Reference run operation (Operating mode 6):
0: Continue reference run
1: Hold axis with
stop delay (FbPosCommonData)
n
Coupled operation (operation mode -12)
0->1 Takeover of gear factor
m
Bit 9: Change of set value
n
Target Position Setting (Operating mode 1)
Change of set value with "set-of-set values"
0: Ongoing positioning operation is ended (target speed = 0; "Set Value reached" is
set) before the next operation is started.
1: Positioning with the current profile speed up to the current target and a running
start to the next positioning operation from this target.
m
Bit 11:
n
Manual drive operation (Operating mode 5):
1: Jog forwards
n
Target Position Setting (Operating mode 1)
1: Start positioning if control of positioning is via "Start positioning"
n
Position control (Operating mode -4):
1: Inhibit set values (Position set values which are written to P136.3/5 or P136.4/6
are not adopted)
n
Spindle positioning
Start of a sequential positioning
m
Bit 12:
n
Manual drive operation (Operating mode 5):
1: Jog backwards
n
Target Position Setting (Operating mode 1):
stop delay (FbPosCommonData)
n
Position control (Operating mode -4):
1: Inhibit set values (Position set values which are written to 136.3/136.5 or
136.4/136.6 are not adopted)