Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
630
4.8
4.8.7.2 Description of the Parameters
145.1
Status
Remarks:
m
Bit 5 Slave axis stopped
This bit is used when the slave axis was stopped using the Stop command of the con-
trol word (
Bit 8 = 1). The slave axis was disconnected from the master axis.
If the Stop command of the control word is canceled, the Bit will be deleted again.
145.6
Synchronization velocity win-
dow
UDINT
1
2147483647
10000
Inc/ms 10000:1
X
145.7
Synchronization acceleration UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.8
Synchronization deceleration UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.9
Synchronization maximum
jerk
UDINT
1
6553600
1000
Inc/
ms³
10000:1
X
X
145.10
Virtual master speed set
value
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.11
Virt. master set value cycle
time
UINT
1
128
1
ms
1:1
X
145.12
Master speed
DINT
-2147483647
2147483647
0
Inc/ms 10000:1 X
145.13
Master position revolutions
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.14
Master position angle
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.15
Master speed set value addi-
tive 1
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.16
Master speed set value addi-
tive 2
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.18
Master angle offset
DINT
0x80000000
0x7FFFFFFF
0x0
Inc
1:1
X
Bit no.
Meaning
0
1: Synchronous operation is switched on
3 … 1
Reserved
4
1: Overspeed detected at the transmission input
5
1: Slave axis stopped
7 … 6
Reserved
8
0: Speed synchronization on master axis is completed
1: Speed synchronization on master axis is active
9
1: Slave axis is outside of the synchronization velocity window (
15 … 10 Reserved