Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
312
4.4
170.3
Task control word
From controller firmware version V01.08 the controller PLC supports several tasks in dif-
ferent time levels, which can be run simultaneously. A task, which can be activated/deac-
tivated separately, is assigned to each bit of this parameter.
Bit value = 0: Task is deactivated
Bit value = 1: Task is activated
Bit no.
Meaning
0
Effective status
1: PLC is stopped
1: PLC is started
2 ... 1
Start option
00: Stop
01: PLC has been started with cold start
10: PLC has been started with warm start
11: PLC has been started with hot start
3
Error status
0: No error
1: Error (PLC in RUN mode or STOP mode, depending on error)
4
Translation status
0: Translation active
1: Translation completed
5
Translation error status
0: No translation error
1: Translation error
15 ... 6
Reserved
Bit no.
Meaning
0
Default task
1
Task RT0
2
Task RT1
3
Task RT2
4
Task fieldbus
5
Write to parameter PlcEventWrUint
6
Write to parameter PlcEventWrUdint
7
Write to parameter PlcEventWrReal
15 ... 8
Reserved