TDI Nitro-Save NS16 Operating Instructions Download Page 1

3-31-2017 Page 

 

 

3351 East. Hemisphere Loop 
Tucson, AZ  85706 
Phone: (520) 799-8000 
Fax:  (520) 799-8002 
E-mail: [email protected] 
www.tdiinternational.com  

 

TDI Humidity Control Monitor 

#NS16 NITRO-SAVE® 

 

OPERATING INFORMATION 

The TDI Nitro-Save® Humidity Control Monitor is designed to control Nitrogen/CDA flowrate to accurately lower 
humidity in desiccator storage cabinets.  This unit displays temperature as well, but is not calibrated to monitor it. 

CAUTION 

The NS16 Humidity Control Monitor is ONLY to be used with the solenoid flow control valve that is supplied.  This 
valve is designed and specially wired to operate this unit.  Use of any other device will void the 6 month warranty 
and may cause serious damage. This unit is designed and calibrated to be used with nitrogen or CDA. 
 
Stored parts should be a minimum of 1 ½” away from the sensor probe.

 

START UP 

 
To start the Nitro-Save®, plug the AC adapter into an electrical outlet, and then connect it to the port located on the 
back of the monitor.  The monitor will automatically start to measure and display the temperature and humidity 
readings. 
 

 

 

 
 
NOTES: 

 

Use only with the supplied AC adapter.

 

 

FOR INDOOR USE ONLY.  Contact with water or use in dusty conditions may cause damage or affect 
calibration.

 

 

Must Operate at 80 PSI (min) to 100 PSI (max) for Optimum Performance

 

 

To begin and display the main menu press  

 

 
 
 
 

Summary of Contents for Nitro-Save NS16

Page 1: ... is designed and specially wired to operate this unit Use of any other device will void the 6 month warranty and may cause serious damage This unit is designed and calibrated to be used with nitrogen or CDA Stored parts should be a minimum of 1 away from the sensor probe START UP To start the Nitro Save plug the AC adapter into an electrical outlet and then connect it to the port located on the ba...

Page 2: ...ngs to display the current high humidity setpoint This setting defines the highest humidity reading allowed If the humidity rises above this setpoint nitrogen gas will be automatically dispensed until the humidity falls below the high humidity setpoint The display will show the current settings as follows The current high humidity setpoint will be displayed next to High Audio Alarm indicates wheth...

Page 3: ...ease or decrease the RH setpoint Audio Alarm The audio alarm setting allows users to enable or disable the alarm for a high humidity condition To change the current alarm condition arrow down to Audio and press you may then use the up and down arrows to select YES or NO When finished use the arrows to highlight Done and press to return to the previous menu CHECK HIGHS LOWS The Nitro Save maintains...

Page 4: ...eed to be accurate to 2 Relative Humidity 3 80 RH CUSTOMER SERVICE Warranty TDI International Inc warrants this product to be free from defects in materials and workmanship for a period of six 6 months from the date of purchase TDI International Inc will repair problems that occur during the warranty period and that have not been caused by abuse or misuse at no charge to the customer TDI Internati...

Reviews: