Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
123
4
19.10
Motor nominal torque current
Display of the nominal torque current I
sq-nom
, comprised of the motor nominal current I
nom
(
) less the field current.
ASM (I
sd-nom
= Magnetizing current
):
SM (I
sd-nom
= 0, or << I
nom
, is assumed):
19.11
Ke factor in V/Nnom
Ke factor in V/N
nom
or the effective value of the phase-to-phase induced voltage at the
nominal speed. It results from the parameters
Ke
factor (in V/1000 rpm) at a magnetic flux = 100%.
in the enabled state is changed then the internally used
value in the controller is smoothed in order to reduce interferences in the controller. The
temporal change of the smoothing Ke factor can be monitored in the parameter
19.11
.
19.12
Frequency of the current filter
Cut-off frequency of the iq set value filter. The filter is switched off by setting this param-
eter to 0.
19.17
Isq additive set value
Additional set value for current.
19.18
Phi electric
Visualization of the electrical angle (360 degrees = 0xFFFF).
I
sq-nom
I
2
nom
I
2
sd-nom
–
=
I
sq-nom
I
nom
=