![Baumuller b maXX BM2500 Operating Manual Download Page 392](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400392.webp)
Management
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
392
4.5
4.5.5.4 ProDrive Signal bus
Figure 131:
ProDrive Signal bus
4.5.5.5 Parameter overview
Functional block:
FbSignalbus [140]
4.5.5.6 Description of the Parameters
140.1
Mode
Specifies how the Signal bus in the drive is evaluated and actuated.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
140.1
Mode
WORD
0
0xFFFF
0
1:1
X
140.2
Status
WORD
0
0xFFFF
0
1:1
X
Bit no.
Meaning
0
0: Activate Signal bus
1: Completely deactivate Signal bus
1
0: Signal
Chopper Resistor On
is not generated
1: Set
Chopper Resistor On
signal, if the DC link voltage exceeds the bal-
last switch on threshold.
9 .. 2
Reserved
10
0: Evaluate
Supply ready for use
signal
1: Ignore
Supply ready for use
signal