Error descriptions
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
766
5.5
1815
No section exists for motor type plate in
the encoder memory
No section for a motor type plate exists in the encoder OEM mem-
ory.
Pulse block
1816
No section exists for notch position off-
set in the encoder memory
No section exists for notch position offset in the encoder OEM mem-
ory
Pulse block
1817
No section exists for M0 data in the
encoder memory
No section exists for M0 data in the encoder OEM memory
Pulse block
1818
No section exists for operating data in
the encoder memory
No section exists for operating data in the encoder OEM memory
Pulse block
1901
Connection did not exist, client was not
logged in.
No response
1902
GdpProtocol version not supported.
No response
1903
Maximum number of users reached.
No response
1904
Report ID not known. No GDP report
No response
1905
CRC32 checksum does not match the
calculated checksum.
No response
1906
Telegram header size not plausible.
No response
1907
Job length not plausible.
No response
1908
Fragment length not plausible.
No response
1909
Command not yet implemented.
No response
1910
User is already logged in
No response
1911
User is not logged in
No response
1913
Too many parameters have been
requested
No response
1914
The Job ID is wrong in a sequence of
partial telegrams
No response
1915
Wrong count value for Parameter
Read-Write
No response
1917
OrderSpec not supported
No response
1918
Buffer size of small block length not
plausible
No response
1919
Block length smaller than minimum
required size
No response
1920
Too many simultaneously active com-
mand
No response
1921
Command unknown
No response
1922
Wrong list type
No response
1923
Wrong parameter list ID
No response
1924
Wrong parameter number for parame-
ter list
Wrong parameter number for parameter list
No response
1925
Parameter does not exist
No response
1926
List does not exist
No response
1927
Wrong real time mode
No response
1928
Value for Alive Timeout may not be 0
No response
1930
Index range wrong (Start-Index End-
Index or Max-DIM
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response