![Baumuller b maXX BM2500 Operating Manual Download Page 219](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400219.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
219
4
116.4
Target number digital input 1
Number of the parameter to be changed by Digital Input 1.
116.5
Bit selection digital input 1
This parameter specifies which bits of the target parameter will be modified with the bit
pattern Low/High.
If the data of the target parameter is of type Float, no bit selection can be made; all the
bits written to the target parameter will always be of the bit pattern Low or High.
116.6
Set bit pattern for LOW state digital input 1
Bit pattern for logic LOW on Digital Input 1
14
0:
Input is edge triggered
1:
Input is level triggered
15
0:
Input is not inverted
1:
Input is inverted
Bit no.
Meaning
NOTE!
The following inputs are permanently linked to the "Pulse enable" function: DI4
DI1: Digital input measuring probe 1
DI2: Digital input measuring probe 2
NOTE!
The states of the "Quick stop", "Controller enable" and "Error reset" special functions
can be observed in the "Status digital inputs drive manager"
parameter.
The states of the "Negative hardware limit switch", "Positive hardware limit switch"
and "Zero point reference switch" special functions can be observed in the "Status
limit switch"
parameter.