Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
530
4.8
4.8
Operating Modes
4.8.1
Operating Modes general
In this chapter the functions and parameter will be described, which are valid for several
operating modes.
m
Hardware limit switch monitoring
m
Software limit switch monitoring
m
Positioning window monitoring with parameters
and
.
m
Override factor for set value speed via parameter
m
Setting of the delay value at stop request, e.g. from the control word or through a
limit switch via parameter
.
m
Bipolar limit to limit the output speed set value of the active operating mode via
.
m
Parameter to set the load gear, the drive-ended positioning resolution and of the
modulo value
m
Command Moving to positive stop
Overview of the using in the operating modes:
*)
This functions are not effective in the unlisted operating modes.
Operating mode
Hardware
limit
switch
monitoring
Software
limit
switch
monitoring
Position-
ing win-
dow
monitoring
Speed
override
Stop
delay
Speed
limit
Modulo
position
actual
value
Moving
to posi-
tive stop
Spindle position-
ing (-6)
X
X
X
Position control
with synchronous
position set value
specification (-4)
X
X
X
X
X
X
Speed control (-3)
X
X
Target position
setting (1)
X
X
X
X
X
X
X
Speed setting 1
(2)
X
X
Manual drive
operation (5)
X
X
X
X
X
X
Homing (6)
X
X
X
X