Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
513
4
151.5
Lower threshold absolute
If the data type of the parameter selected with
is FLOAT, then this parameter
forces the lower absolute switching threshold.
The absolute two-level controller switches on, if the following is valid:
Parameter number actual value
lower absolute switching threshold
151.6
Upper threshold absolute
If the data type of the parameter selected with
is FLOAT, then this parameter
forces the upper absolute switching threshold.
The absolute two-level controller switches off, if the following is valid:
Parameter number actual value
upper absolute switching threshold
151.10
Target number
Selection of the target parameter of the absolute two-level controller output.
151.11
Bit selection
Selection of the bits to be changed of the target parameter for the absolute two-level con-
troller output.
151.12
Bit pattern LOW
Bit pattern which is written in the target parameter at absolute two-level controller output
LOW (negative edge).
151.13
Bit pattern HIGH
Bit pattern which is written to the target parameter at absolute two-level controller output
HIGH (positive edge).
151.14
Lower threshold absolute UDINT
If the data type of the parameter selected with
is INT, DINT, UINT, UDINT,
WORD or DWORD, then this parameter forces the lower absolute switching threshold.