Model 4200-CVU-PWR 

Parts Package 

 

 

PA-977 Rev. C / September 2016  

*PPA-977C*

Keithley Instruments

 

28775 Aurora Road 
Cleveland, Ohio 44139 
1-800-935-5595

http://www.tek.com/keithley

Introduction 

The Model 4200-CVU-PWR C-V Power Package for both the 4200A-SCS and 4200-SCS enables C-V 
measurements with a DC voltage bias of up to ±200 V or 400 V differential (0 V to ±400 V) and a current output 
of up to 300 mA. Using this package, the 4210-CVU Capacitance-Voltage Unit measures the capacitance and 
either one or two 4200-SMUs or 4210-SMUs are used to supply the DC bias or sweep voltage. 

The next figure shows the hardware that is supplied with this package. The next table lists the hardware, part 
number, and quantity. 

Figure 1: 4200-CVU-PWR package 

Note that the items shipped may vary from the model pictured here. 

Summary of Contents for KEITHLEY 4200-CVU-PWR

Page 1: ...voltage bias of up to 200 V or 400 V differential 0 V to 400 V and a current output of up to 300 mA Using this package the 4210 CVU Capacitance Voltage Unit measures the capacitance and either one or two 4200 SMUs or 4210 SMUs are used to supply the DC bias or sweep voltage The next figure shows the hardware that is supplied with this package The next table lists the hardware part number and quant...

Page 2: ...BTs are required in the test circuit For C V measurements with an applied voltage bias up to 200 V one 4205 RBT is required For C V measurements with a voltage differential up to 400 V two 4205 RBTs are required To make C V measurements with an applied voltage bias up to 200 V connect one 4200 SMU or 4210 SMU source measure unit one 4210 CVU capacitance voltage unit and one 4205 RBT to the device ...

Page 3: ...vsT that allow you to make high voltage C V measurements If one 4205 RBT is used the SweepV module allows you to sweep a DC voltage across the DUT using the 4200 SMU or 4210 SMU and measure the capacitance using the 4210 CVU If two 4205 RBTs are used with the SweepV module one SMU is used to sweep the DC voltage and the other SMU is used to apply an offset DC bias as shown in the previous figure T...

Page 4: ...Configure 5 In the Test Settings pane under User Libraries select hivcvulib 6 In the User Modules list select CvsT or SweepV More detail about the 4200 CVU PWR For more information about using the 4200 CVU PWR with a 4200A SCS go to http www tek com keithley and search for the document named Using the 4200 CVU PWR C V Power Package to Make High Voltage and High Current C V Measurements with the Mo...

Page 5: ...ese instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fixtures The American National Standards Institute ANSI states that a shock hazard exists when volt...

Page 6: ...hat selected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product If you are unsure about the applicability of a replacement component call a Keithley Instruments office for information Unless otherwise noted in product specific literature Keithley instruments are designed to operate indoors only in the following environment Altitude at ...