background image

Dimensions and front 

OI

 22

OI 22 -NTC, PT, J / K / S,

mA, V,

Dimensions and front

DIGITAL INDICATOR 4 digits

1-Set key: 

To enter the parameters menu and allows to modify

them.

2-Key: 

Decreases the programming value of the parameters.

USER MANUAL

INTRODUCTION:

This manual contains the information necessary for correct 

installation and instructions for the use and maintenance of the 

product, therefore it is recommended that you carefully read 

the following instructions.

The same is said for each person or company involved in the 

creation of this manual.

This publication is the exclusive property of OSAKA, which 

prohibits its absolute reproduction and disclosure, as well as 

part of it, unless expressly authorized.

OSAKA reserves the right to make aesthetic and functional 

modifications at any time and without prior notice.

3-Key

: Increases the programming value of the parameters

meters.
Note: The "F" key is displayed neutral because it does not have any 

function.

2 - TECHNICAL DATA

ELECTRICAL CHARACTERISTICS

 

Feeding: 230 VAC +/- 10%. AC 

frequency: 50/60 Hz. Consumption: 3 

VA approx.

Tickets: 1 input for NTC, PT100 and J / K / S type probes and 0 / 

4..20mA and 0..10V signal.

Protection class against electric shock: Class III. Isolation: no 

isolation between supply and input.

INDEX

3

4

5

6

7

8

1                     

GENERAL DESCRIPTION

2                                                                                                   

TECHNICAL DATA

INSTALLATION

PARAMETER PROGRAMMING (OI 22 mA, V) 

PARAMETER TABLE (OI 22 mA, V)

DESCRIPTION OF THE PARAMETERS (OI 22 mA, V) 
TROUBLESHOOTING, MAINTENANCE AND WARRANTY 
HOW TO CHANGE THE DECIMAL POINT IN THE OI 12 NTC, 
PT100, J / K / S, mA and V

MECHANICAL CHARACTERISTICS

 Case: Self-

extinguishing plastic UL 94 V0. Dimensions: 33 

x 75 mm, depth 64 mm. Weight : 180 g approx.

Installation: Recessed in 29 x 71 mm gap panel. 

Connections: Terminal strip for 2.5 mm cable

two

Frontal protection degree: IP 65.

Ambient operating temperature: 0 ... 55 ° C. Operating ambient 

humidity: 30 ... 95 RH% non-condensing.

Transport and storage temperature: -10 ... +60 ° C.

1 - GENERAL DESCRIPTION

The OI 22 model is a digital indicator equipped with 1 input for 

NTC, PT100, J / K / S type probes, and mA and V signals. The 

process value is displayed on a 4-digit red display. 

The front of 

the OI 22 mA or V has keys that are used to configure and 

modify the range

.

FUNCTIONAL FEATURES

Measurement range: depending on the probe used: NTC = -50..100 

ºC; PT100 = -200..850 ° C; J = 0..1000 ° C; K = 0..1370 ° C; S = 0..1760 ° 

C; 0 / 4..mA, 0..10V.

Display resolution: 1 / 0.1 / 0.01 / 0.001. 

Total precision: +/- 0.5% fs. Sampling 

frequency: 130 ms.

Accordance: EEC EMC Directive 89/336 (EN 50081-1, EN 

50082-1), EEC Directive BT 73/23 and 93/68 (Device that 

operates with a nominal voltage lower than 50 VAC and 75 VDC).

OSAKA 

- OI 22-NTC, PT, JKS, mA, V - USER MANUAL - v2.0K - PAG. 

1