Encore Presentation System • User’s Guide
73
3. Hardware Installation
Installation
b.
Using the information from the chart:
•
Connect “direct” sources 1 - 6 to each M/E’s input connectors
on the “
bottom stack
” Processor.
•
Connect “direct” sources 7 - 12 to each M/E’s input connectors
on the “
top stack
” Processor.
c.
Connect unscaled
Background
sources to the bottom stack:
•
Connect background source 1 to input 3A.
•
Connect background source 2 to input 3B.
d.
Connect unscaled
DSK
sources to the top stack:
•
Connect DSK source 1 to input 1A.
•
Connect DSK source 2 to input 1B.
7. Stack
Interconnections
—
a.
Connect the bottom stack’s
DVI Preview Output
to the top stack’s
Background 1 input (
3A
).
b.
Connect the bottom stack’s
DVI Program Output
to the top stack’s
Background 2 input (
3B
).
8. D/A Connections —
a.
If your system includes analog, SDI or DVI D/As, connect video inputs to
the D/As as required.
b.
Connect D/A outputs to the to the desired M/E input connectors.
9. Router
Connections
— if you elect to use router connections, in place of (or in
addition to) direct connections:
a.
For Ethernet controlled routers:
•
Ensure that the router(s) are connected to the same Ethernet
Switch as the Controller and Processors.
•
Ensure that each router has an unique IP address.
b.
To connect a single serial controlled router, use an RS-232 cable to
connect the router to the Controller’s
EXT COMM
port. In Chapter 2,
refer to the “
Controller Rear Panels
” section on page 49 for details.
c.
To connect two (or more) serial routers, a third-party Ethernet-to-Serial
converter is required, such as the
Lantronix
model
UDS100
or
UDS200
(
http://www.lantronix.com/pdf/UDS200_PB.pdf
). Note that each
UDS200
can control two serial routers.
•
Using RS-232 cables, connect each router to the
UDS200
.
•
Set up a static IP address on the Lantronix. The recommended
range is
192.168.0.191 - 192.168.0.240
.
•
Using an Ethernet cable, connect the
UDS200
to the same
Ethernet Switch as the Controller and Processors.
d.
Ensure that all sources are connected to your router(s).
e.
Connect all selected router outputs to the desired M/E inputs:
•
For PIPs 1 - 6, connect router outputs to the desired M/E inputs
on the “
bottom stack
” Processor.
•
For PIPs 7 - 12, connect router outputs to the desired M/E
inputs on the “
top stack
” Processor.
Summary of Contents for Encore
Page 1: ...r d b m p Manual 26 0313000 00 Revision B...
Page 16: ...16 Encore Presentation System User s Guide Table of Contents...
Page 38: ...38 Encore Presentation System User s Guide NK f What s New in the User s Guide Rev B...
Page 211: ...Encore Presentation System User s Guide 211 5 Menu Orientation Crop Menu...
Page 340: ...340 Encore Presentation System User s Guide 7 Operations Working with the DSK...
Page 374: ...374 Encore Presentation System User s Guide aK t t a ImagePRO Aux Configuration...
Page 404: ...404 Encore Presentation System User s Guide Index...