![Barco Encore Manual Download Page 56](http://html1.mh-extra.com/html/barco/encore/encore_manual_3871756056.webp)
56
Encore Presentation System • User’s Guide
3. Hardware Installation
Installation
Use the following steps to install a single screen Encore configuration:
1.
Follow the unpacking procedures as listed in the “
Unpacking and Inspection
”
section on page 52.
2.
In Appendix A, refer to the “
Physical and Electrical Specifications
” section on
page 344 for electrical and mechanical details.
3.
In Chapter 2, refer to the “
Video Processor Rear Panel
” section on page 41 and
the “
Controller Rear Panels
” section on page 49 for all connector locations.
4.
For the Processor, follow the rack mount procedures as outlined in the “
Rack-
Mount Installation
” section on page 52.
5. Ethernet
Connections
— a totally “local” network connection is recommended,
without IP connections to the outside world. Using Ethernet cables:
a.
Connect the Processor and Controller to the Ethernet Switch.
b.
Connect router(s) to the Switch.
c.
As required, connect ScreenPRO-II, PresentationPRO-II and ImagePRO
systems to the Switch.
6. Direct Source Connections
— if you elect to use direct connections, in place of
(or in addition to) router connections:
a.
As an important prerequisite, complete your “
Connection Charts
” on
page 80 to streamline your source installation procedure.
b.
Using the information from the chart, connect the desired “direct”
sources to each M/E’s input connectors as required.
c.
As required, connect unscaled background and DSK sources, as
provided from a PC’s single head graphics card.
7. D/A
Connections
—
a.
If your system includes analog, SDI or DVI D/As, connect video inputs to
the D/As as required.
b.
Connect D/A outputs to the to the desired M/E input connectors.
8. Router
Connections
— if you elect to use router connections, in place of (or in
addition to) direct connections:
a.
For Ethernet controlled routers:
•
Ensure that the router(s) are connected to the same Ethernet
Switch as the Controller and Processor.
•
Ensure that each router has a unique IP address.
b.
To connect a single serial controlled router, use an RS-232 cable to
connect the router to the Controller’s
EXT COMM
port. In Chapter 2,
refer to the “
Controller Rear Panels
” section on page 49 for details.
c.
To connect two (or more) serial routers, a third-party Ethernet-to-Serial
converter is required, such as the
Lantronix
model
UDS100
or
UDS200
(
http://www.lantronix.com/pdf/UDS200_PB.pdf
). Note that each
UDS200
can control two serial routers.
•
Using RS-232 cables, connect each router to the
UDS200
.
•
Set up a static IP address on the Lantronix. The recommended
range is
192.168.0.191
-
192.168.0.240
— so as not to conflict
with Encore devices. See the
Lantronix User’s Guide
.
•
Using an Ethernet cable, connect the
UDS200
to the same
Ethernet Switch as the Controller and Processor(s).
Summary of Contents for Encore
Page 1: ...r d b m p Manual 26 0313000 00 Revision B...
Page 16: ...16 Encore Presentation System User s Guide Table of Contents...
Page 38: ...38 Encore Presentation System User s Guide NK f What s New in the User s Guide Rev B...
Page 211: ...Encore Presentation System User s Guide 211 5 Menu Orientation Crop Menu...
Page 340: ...340 Encore Presentation System User s Guide 7 Operations Working with the DSK...
Page 374: ...374 Encore Presentation System User s Guide aK t t a ImagePRO Aux Configuration...