NetLinx Programming
108
TPI-PRO/DVI (Total Presentation Interface)
"^" Button Commands (Cont.)
^BOR
Set a border to a
specific border
style associated
with a border
value for those
buttons with a
defined address
range.
Refer to the
Border Styles By
Name table on
page 90.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variables:
• variable text address range = 1 - 4000.
• border style name = Refer to the Border Styles By Name table on page 90.
• border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of 500-504
& 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
The border style is available through the TPDesign4 border-style drop-down list. Refer to
the
section on page 90 for more information.
^BOS
Set the video
window slot ID #
to the new Slot
ID#.
The new Slot ID # is set only if the specified slot is not the same as the current slot
selected.
Note: This is an optional parameter and ONLY passes data to the PC.
Syntax:
"'^BOS-<vt addr range>,<button states range>,<slot number>,
<touch pass through (optional)>'"
Variables:
• variable text address range = 1 - 4000.
• button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons,
1 = Off state and 2 = On state).
• slot number =
0
= No Video Fill (
Video Off
)
1 - 4
= Video Fill (
Video On
)
• touch pass through (optional) - If not present, assumed Touch Pass Through is off.
0
= Turn off Touch Pass Through
1
= Turn on Touch Pass Through
Example:
SEND_COMMAND Panel,"'^BOS-500,1,0'"
Sets the button to display no video fill, and disables Touch Pass Through.
Example:
SEND_COMMAND Panel,"'^BOS-500,1,2,1'"
Sets the button to display video in Slot 2, and enables Touch Pass Through.
Refer to the
section on page 64 for more information on the
slot assignments within a panel.
^BPP
Set or clear the
protected page flip
flag of a button.
A value of zero (0) clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variables:
• variable text address range = 1 - 4000.
• protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).
Summary of Contents for TPI-PRO-4
Page 14: ...xii TPI PRO Total Presentation Interface Table of Contents ...
Page 76: ...TPI PRO DVI Configuration Pages 70 TPI PRO DVI Total Presentation Interface ...
Page 172: ...Terminal Telnet Commands 166 TPI PRO DVI Total Presentation Interface ...
Page 180: ...Upgrading Firmware 174 TPI PRO DVI Total Presentation Interface ...
Page 208: ...Supported Input and Output Modes 202 TPI PRO DVI Total Presentation Interface ...
Page 214: ...Appendix 208 TPI PRO DVI Total Presentation Interface ...
Page 217: ...Troubleshooting 203 TPI PRO Total Presentation Interface ...